If you have to pump a liquid up 30 feet and your pump doesnt have at least 30 feet of head, then there is no chance it will work. With an increase in pump flow rate, the head developed by the pump start decreases. Sometimes head can be confused with pressure during pump choice. In practice the combined head and volume flow moves along the system curve as indicated from 1 to 3. Using the doubling flow rate rule, the 200 gpm flow rate with its head loss of 2. The flow rate is the effective volume flowing per unit of time through the discharge connection of a pump. Pipe flow expert modelling positive displacement pumps. Depending on the required delivery head, the centrifugal pump will find its operating point when the plant curve and pump curve meet. The steps to follow to select a centrifugal pump are. Make sure the aquifer is capable of supporting your desired flow rate. The relationship between the capacity or flow rate versus travel follows a specific curve. What is total head 10 what is the relationship between head and total head 11.
It is recommended to select a flow that is higher than the minimum to account for decrease in flow that naturally occurs as the filter becomes loaded with dirt and debris. This can be applied to pumps within hvac industry such as chilled water pumps. Once the flow rate q is defined and the delivery head h is calculated, the operating point of the plant can be determined. Pumps can generate high volume flow rates when pumping against lowpressure head or low volume flow rates when pumping against highpressure head. The system head increases as the flow rate increases. Hence, there is a certain flow at which both the system and pump head curves match. Topics covered include total dynamic head, lift, loss, flow, pressure, friction loss head loss, and converting psi to feet. Head loss does not reduce the fluid velocity consider a constant diameter pipe with a constant mass flow rate, and it will not be effect the elevation head of the fluid consider a horizontal pipe with no elevation change from inlet to outlet. The total head is the effective mechanical energy transferred by a pump to the fluid as a function of the weight force of the fluid. Note thatqis also used as the symbol for heat transfer. Using the doubled rate, the 400 gpm flow rate with its corresponding 8.
Most pump applications involve moving fluid to a higher level. In this example, if pumping against a head of 40 ft using an impeller size of 7. As a matter of fact there is a strict relation between them which is defined by the fluid specific gravity, so the relation is fluid dependent. Typical selection criteria for centrifugal pumps are their design data flow rate or capac ity q, discharge head h, speed of rotation n and npsh, the.
A pump has been selected f rom manufacturers details that can achieve the required flow at the bwl at a speed of 675 rpm. The pump develop maximum head at zero flow it is called shutoff point or shutoff head and the corresponding pressure is called shutoff pressure. Flow rate and flow head can be influenced via the control fittings installed in the delivery pipe. The most common shape of a total head against capacity curve for a conventional volute centrifugal pump is shown in figure 4.
Pump performance curve a centrifugal pump performance curve is a tool that shows how a pump will perform in terms of head and flow. When we talk about how much water a pump will move, the volume, we will refer to the max flow rate as measured in gallons per minute gpm. Pump head, on the vertical axis, is the difference between system back pressure and the inlet pressure of the pump dppump. Pdf dimensionless characteristics of centrifugal pump. Current the amount of electricity measured in amps which is flowing in a circuit. Swpa handbook and the hydraulic institute for the above terms. Review different pump types commonly used understand the difference between centrifugal. For a given pump speed, as defined on the xaxis, each flow rate pump head data point can be derived by identifying the point where each pressure line crosses the xaxis for the selected pump speed.
Relationship between pressure drop and flow rate in a. These curves define the envelope of the pumping system. Pump operation and performance can best be described by a few fundamental parameters. The possible combinations of total pressure and volume flow rate for. Power input the electrical input to the motor expressed in kilowatts kw. This is the first video in our new series on buying a pump and the. Because pressure drop varies with the square of flow rate, the equation of the system curve can be estimated by fitting a quadratic equation through the origin and the design operating point. The geometries of the two pumps are designed for the same flow rate and shut off head coefficient with the same impeller rotational speed. The pump curves show a comparison of flow rates in congruence with horsepower and feet of head. Engineers have a common language and analytical models to describe pump performance. To size and select a centrifugal pump, first determine the flow rate. They provide lift which overcomes head pressure, which is measured in feet. Centrifugal pumps are characterized by the relationship between the flow rate q they produce and the. Head pump head and shutoff head pressure explained.
Flow rate depends on elevation difference or static head 7. The maximum total head developed by the pump is at zero capacity. Examples of total head calculations sizing a pump for a home owner application. The system curve c describes the relationship of pressure drop and flow rate for the given piping system with no static head. Manual for the design of pipe systems and pumps gea group. In order to optimize the pump design, the flow rate must be accurately determined. Alhough certain system head parameters are calculated the same way whether the driving force for flow is a pump or gravity, this article mainly addresses sizing concerns for rotodynamic pumps.
Improve flow rate by understanding control valves pumps. Pd flow rate is relatively independent of viscosity. Pump sizing and selection made easy chemical engineering. The pump selection of a pump is driven by the following main parameters. As shown in the sample performance curves, usually 3 curves of differential head vs. That zone is where the pump operates most efficiently. Axialflow pumps lower pressures and higher flow rates than radialflow pumps. In a system where there is flow, the total head is the difference between the discharge head and the suction head plus the friction head and this sum will be less than the shutoff head. Flow friction head sometimes called dynamic head loss is the friction loss, on the liquid being moved, in pipes, valves and equipment in the system. On the other hand, the highpressure series keeps a steady rate of climb as the feet of head peaks. Pumps and pumping system bureau of energy efficiency 115 figure 6. Conversely, if the pump is located above the water to be pumped, then the suction head is positive and the pump head will decrease.
Flow rate q 4 head h metres 4 performance range 60 hz n 3450 rpm nomenclature singlephase motor flow rate us g. Pump performance the pump converts electrical power into. Typical centrifugal pumps will show an increased flow rate as head pressure decreases. The centrifugal pump head, on the other hand, decreases as the flow increases. Total head for a given flow rate will have determined the impeller diameter to select according to the performance curve. The plot of head versus flow rate is known as the pumps performance curve see figure 7 for an example of a pump performance curve. The initial flow is 100 gpm, the initial head is 100 ft, the initial power is 5 bhp, the initial speed is 1750 rpm and the final speed 3500 rpm. For a centrifugal pump what is the relation ship between. This curve can be used with a shear rate curve for the tubing that is used in the system, to determine the apparent viscosity. The pump speed is changed when the impeller size is constant.
In any one application these parameters may be more or less important. Changing the travel of a control valve will change flow rate. Determine the flow rate and developed head for the pump used. If you are a home owner, find out which of your uses for water is the biggest consumer. The total head is the effective mechanical energy transferred by a pump to the fluid as a. Solution first determine the head flow characteristic for the system. Friction head loss the resistance to water flow, as expressed.
Centrifugal pumps in parallel are used to overcome larger volume flows than one pump can handle alone. When reading these curves while choosing a pump, there is a certain optimum zone on the pumpcurve graph that you want to stay in. Head vs flow curve hq in this curve, the head is on the vertical axis and flow rate on the horizontal axis. The head pressure against which a submersible pump operates is referred to as total dynamic. A comparative study on centrifugal pump designs and two. Therefore, head loss will always act to reduce the pressure head, or static pressure, of the fluid. Pump selection, sizing and interpretation of performance curves 4 7 practice to plot the system curve for higher flow rates than the design flow rate, since flow demand may change and extra capacity may be required.
Pump flow is taken at the largest impeller diameter for double suction impellers pump flow is divided by two ns specific speed n pump speed, rpm q flow, m3h h head, m values are taken at best efficiency point bep pump flow is taken at the largest impeller diameter for double suction impellers pump flow is divided by two. Pump design equations formulas calculator discharge flow rate. Crescent is attached to pump head crescent is stationary and separates the rotor and idler teeth, providing the. In practice, to get the optimal system you have to select the pump capacity i. The high flow challenger on the right shows a sharp dip as the feet of head pressure rises. Hayward hydraulics and pump sizing for existing pools. Pump sizing involves matching the flow and pressure rating of a pump with the flowrate and pressure required for the process. Pump efficiency is the best combination of head and flow at the least energy consumption. Usually the operating point is not on the qh curve of the pump. Flow is indicated on the xaxis while pressurehead is indicated on the yaxis. The flow rate between the minimum flow based on the turnover rate and the maximum flow based on water velocity. This is because the pump must use energy to bring the water to the level of the pump.